Note: In the back of North hall (B2) power is not available from the floor, all power must come from overhead.
Location of Power in Your Booth:
Inline and Peninsula Booths: Power will be installed in one location, typically on the floor somewhere along the back of the booth, as indicated in the below diagrams. Note: We cannot guarantee that the outlet will be specifically located in the middle.
If power is required in locations other than indicated above, secondary distribution will be required and billed on a time and material basis. Please complete and submit an Electrical floor plan as described below with your power order. If you prefer to be on-site to supervise the installation of your labor, please request online.
Island Booths/Multiple Outlets: Floor plans are always required for Island Booths and orders for multiple outlet locations. The floor plan must indicate booth dimensions, surrounding booth numbers for orientation within the facility, each outlet location, required wattage or amperage and location for main drop. If power location in an island booth is not provided prior to show move-in, power will not be installed and can result in significate delays. Relocation of the service will be charged on a time and material basis. See examples below: A grid is available online to print as a base layout.
ELECTRICAL INSTRUCTIONS
1. Labor rates are based on current wage scales and are subject to change in the event of a wage increase after rates have been published.
2. A minimum charge of a 1/2 hour is applicable to all labor requests. Additional time on the same day is billed in 1/2 hour increments. Continuations to another day are a minimum of a 1/2 hour.
3. Labor must be picked up at the PES Electrical Desk. Charges for labor commence at time of dispatch to service the labor call. A 1/2 hour minimum will apply if an exhibitor representative is not present at the time of call or reschedules the call, unless 24 hour advance notice is received in writing.
4. Labor charges will include the time for electricians to gather the necessary tools and material for the job, have their work checked by the client and return the tools and material to the supply area.
5. Exhibitors may supply their own 14 gauge 3 wire, extension cords and/or power strips, both of which must be grounded and UL approved.
EXAMPLE OF PLAN AND INFORMATION REQUIRED TO COMPLETE FLOORWORK
Please indicate the following on the floor plan.
1. Location and load of main power drop - please provide specific dimensions and wattages/amperages.
2. Location and load of all outlets - please provide specific dimensions and wattage, amperage and voltage.
3. All Outlets - please identify any overhead outlets
4. Booth orientation - please provide surrounding aisle and/or booth number